Air Induction System Wastewater Aeration, Case Study

May 4th, 2017

CASE STUDY Wastewater Aeration Global Treat Inc. Provided a Texas Wastewater Treatment Plant with an Air Induction System that resulted in a Cost-effective Solution to Maintaining the Required Level of Dissolved Oxygen (DO). Fredericksburg, TX Case Study Video – The Problem: In September, 2016, the City of Fredericksburg Wastewater Treatment plant experienced a failure with their existing air induction system. Following the equipment failure, Mr. Lyle Durst, Wastewater Treatment Plant Manager, contacted Global Treat, Inc. to request an evaluation of their application. Mr. Durst’ primary objective was to replace the city’s existing air induction system with a reliable and competitively …
Learn More

Global Treat, Inc. Trade Show Schedule

March 7th, 2017

  Global Treat, Inc. 2017 Trade Show Schedule February 7-8, 2017 New Orleans, LA Cooling Tower Institute 2017 http://www.cti.org/ February 16-18, 2017 Texas Wine & Grape Growers Conference (TWGGA) San Marcos, TX 2017 Conference & Trade Show Feb 28-March 2, 2017 Texas Water Utilities 2017 Annual School Corpus Christi, TX http://twua.org/ March 29-31, 2017 RuralWaterCon 2017 (TRWA) Austin, TX http://www.trwa.org/events/EventDetails.aspx?id=912927&group= April 10-13, 2017 Texas Water 2017 Austin, TX https://www.txwater.org/index.cfm May 8-11, 2017 TWUA Central West Texas Regional School Abilene, TX http://www.twua.org/index.php/training/classes/regional-schools June 15-16, 2017 TWUA Conference Austin, TX http://twua.org/index.php/about-us/important-dates August 8-9, 2017 TCEQ Public Drinking Water Conference Austin, TX https://www.tceq.texas.gov/drinkingwater/conference.html …
Learn More

Chlori-Flush Water Disinfection System

September 19th, 2016

According to the American Water Works Association (AWWA) standards, all new water mains must be disinfected before they can go into service.  In addition, all existing water mains and water holding tanks that have been removed from service for inspections, repairs, or other activities must be disinfected before returning to service.  Preventing contamination of water lines is essential in both new potable distribution lines as well as existing water distribution lines that have been compromised due to repairs or during maintenance. Global Treat’s newest product, the Chlori-Flush Water Disinfection System offers an effective disinfection solution to rid systems of potentially …
Learn More

When does it make sense to use a vaporizer?

September 19th, 2016
Model VPH-10000-2

In high capacity chemical feed applications, when does it make sense to use a vaporizer as opposed to the typical direct gas withdrawal system? A vaporizer should be considered if the following conditions make a direct gas withdrawal system impractical. Large withdrawal rate > (3000 PPD; 60 kg/hr.) Gas withdrawal of 500 PPD (10kg/hr) per ton container Liquid withdrawal of 10,000 PPD (200 kg/hr) per ton container Gas withdrawal requires too many online containers Global Treat, Inc. offers the electronically heated Hydro Instruments Series VPH-10000 Vaporizers that are used to convert liquid chlorine, sulfur dioxide, or ammonia into a superheated …
Learn More

Acid Eddy Chemical Dilution Trough

September 19th, 2016
acid eddy chemical dilution

An “Eddy”, in fluid dynamics, is defined as situation where a current of water is moving in a direction that is different from that of the main current. Global Treat, Inc. uses this hydraulic event (eddy) for mixing and diluting acids in process water used in cooling towers via the “Acid Eddy Chemical Dilution Trough.” So, the question is:  Is it possible to reduce corrosion and extend the life of cooling tower basins with the use of a chemical dilution trough? And the answer is – Yes!  The Acid Eddy was designed to extend the life of cooling tower basins …
Learn More